Induction Forge Coil Maker’s Companion

Experimental coil-design aid for common 15 kW high-frequency induction heaters. Recommendations are based on practical coupling geometry and machine-family reference coils, not a full electromagnetic simulation.

Workpiece & machine

Length of bar you would like to heat in one stationary heat. The calculator will warn if that is impractical for the machine, stock, or coil geometry.
Calculated automatically from the bar size and geometry for practical forging clearance and efficient heating.
Calculated automatically. The calculator will recommend how far the wound heating section should begin from the machine/quick-connects, then estimate the copper used by both leads and their bends/transitions. This keeps a new coil maker from having to guess a lead allowance.

Always test at reduced heat time first. A coil that is electrically mismatched can cause poor output, machine alarms, excessive current, or component stress.

Recommendation

—
Enter dimensions
Fill in the workpiece dimensions and calculate.
Recommended turns—
Coil inside size—
Clearance between bar and coil—
Wound coil width—
Recommended distance from quick-connects to first active turn—
Gap between coil turns—
Total copper tubing needed for this coil—
Copper length vs. machine limit—
Estimated single-heat capability—
Machine-start / load risk—